Part of the SAUTER modulo 6 system family
Modular automation station, expandable with I/O modules and communication modules
Regulation, control, monitoring and optimisation of operational systems in HVAC engineering
Locally expandable with up to 24 modules via the SAUTER Extension Bus
Can be locally equipped with ecoLink I/O modules and ASV actuators via SLC interface
Two RJ45 connections switched for daisy chain
BACnet/IP with device profile B-BC (EN ISO 16484‑5)
AMEV AS-B profile
With function expansion:
BACnet/SC (encrypted communication)
MQTT interface (MQTT Broker/Client)
REST API interface
Integrated web server for local commissioning, expandable with visualisation and operation
User administration for identification, authentication and access control
Encryption of communication with TLS
Bluetooth interface for mobile commissioning and maintenance
Programming/parameterisation via PC using CASE Suite (based on IEC 61131-3)
Control libraries
Time and calendar function
Predictive control based on meteorological forecast data
Data recording on removable media (microSD card)
User administration and user identification (web server)
Alive signal output pulsed
TLC TECHNICAL SERVICE TRADING COMPANY LIMITED
219/8 Duong so 5 Khu pho 3, Binh Hung Hoa Ward Binh Tan District, Ho Chi Minh City, Vietnam. Tel. +84 (0) 90 2540 929 long.nt(at)tl-controls(dot)com http://www.tl-controls.com/ Sauter Building Control International GmbH Hans-Bunte-Strasse 15 DE-79108 Freiburg i. Br. Tel. +49 761 510 54 05 Fax +49 761 510 54 20 ms.sbci(at)de.sauter-bc(dot)com www.sauter-controls.comSAUTER Head Office was the target of a cyber security incident on November 20, 2024. SAUTER’s IT department immediately activated, well defined, internal emergency plans. All IT systems were completely isolated and shut down to successfully prevent the attack from spreading. External cybersecurity experts and data forensics specialists then began to check all systems and restore them securely. This process is unfortunately time-consuming, but absolutely necessary to ensure that the cyber-attack does not continue at a later date.
The SAUTER websites have been affected by the emergency operation and are available again with immediate effect.
There are currently no concrete indications that our customers' infrastructures have been compromised in any way by SAUTER devices. It appears to be an opportunistic incident with no clearly recognisable long-term goals or systematic attacks. The situation does not currently suggest that there is a targeted, sustained threat to the affected systems.
You need to load content from reCAPTCHA to submit the form. Please note that doing so will share data with third-party providers.
More Information