How energy efficiency is improved
Convenient time programme that enables the system to be adjusted to the individual requirements of the user, and also to be switched off temporarily if required
Weather-dependent supply temperature control by heating curve or 4-point characteristic and drinking water heating
29 system models, for example for district heating, single-stage boilers, drinking water heating with solar energy or buffer tank.
Convenient to use with modern operating concept (turn and press) and large LCD
Convenient weekly and annual switching programmes with optimisation of switching times
Automatic summertime/wintertime changeover
Min./max. limitation of supply temperature and max. limitation of return temperature
Frost-protection facility and anti-jamming function for valve and pump
Floor-drying function
Function for protecting against legionellae
Room temperature switching using room-temperature sensors
Ni/PT1000 inputs for the outside, supply, drinking water, return flow and room temperature
Relay outputs with varistor suppression for activating control units and pumps
Manual mode
Logbook (only EQJW146F002)
Configurable input/output 0…10 V
External demand processing, binary or analogue (0..10 V)
Interface for various accessories such as modem, gateway, data logging module etc.
TLC TECHNICAL SERVICE TRADING COMPANY LIMITED
219/8 Duong so 5 Khu pho 3, Binh Hung Hoa Ward Binh Tan District, Ho Chi Minh City, Vietnam. Tel. +84 (0) 90 2540 929 long.nt(at)tl-controls(dot)com http://www.tl-controls.com/ Sauter Building Control International GmbH Hans-Bunte-Strasse 15 DE-79108 Freiburg i. Br. Tel. +49 761 510 54 05 Fax +49 761 510 54 20 ms.sbci(at)de.sauter-bc(dot)com www.sauter-controls.comSAUTER Head Office was the target of a cyber security incident on November 20, 2024. SAUTER’s IT department immediately activated, well defined, internal emergency plans. All IT systems were completely isolated and shut down to successfully prevent the attack from spreading. External cybersecurity experts and data forensics specialists then began to check all systems and restore them securely. This process is unfortunately time-consuming, but absolutely necessary to ensure that the cyber-attack does not continue at a later date.
The SAUTER websites have been affected by the emergency operation and are available again with immediate effect.
There are currently no concrete indications that our customers' infrastructures have been compromised in any way by SAUTER devices. It appears to be an opportunistic incident with no clearly recognisable long-term goals or systematic attacks. The situation does not currently suggest that there is a targeted, sustained threat to the affected systems.
You need to load content from reCAPTCHA to submit the form. Please note that doing so will share data with third-party providers.
More Information