Fume-cupboard indicator and monitor

FCCP 200

Fume-cupboard indicator and monitor

How energy efficiency is improved

Display and interface for safe, energy-efficient monitoring of fume cupboards, pressure zones and other ambient conditions with an attractive design and state-of-the-art technology


Funktioner

  • Measured value display and indication of operating statuses for a range of ambient conditions such as pressure, temperature, relative humidity etc. in combination with an EY‑RC 504/505 room automation station or an ASV 2*5 VAV compact controller

  • Monitoring fume cupboards as per EN 14175‑2 to check that they are functioning correctly and that the ventilation is operated to provide maximum safety for the laboratory staff

    • Indication when the front sash is open > 500 mm

    • Switching the fume cupboard lighting on and off

    • Up to two function indicators for double-sided fume cupboards

    • Indication of day/night change-over

    • Audible alarm can be delayed or muted via configuration

  • Demand-controlled regulation of fume cupboards as per EN 14175‑6 in combination with the ASV 2*5 VAV compact controller

  • Function indicator with visual and audible notification as per EN 14175‑2

  • Storage of all defined parameters with protection from power failure

  • Interface for easy configuration of the connected VAV ASV 2*5

  • Five freely configurable push-buttons

  • Chemical-resistance glass surface

  • Units that can be displayed: m/s, fps, l/s, m3/h, cfm, Pa, °C, °F, %rh, ppm

Produktsökning
© 2024  Fr. Sauter AG Alla rättigheter förbehållna

SAUTER Head Office was the target of a cyber security incident on November 20, 2024. SAUTER’s IT department immediately activated, well defined, internal emergency plans. All IT systems were completely isolated and shut down to successfully prevent the attack from spreading. External cybersecurity experts and data forensics specialists then began to check all systems and restore them securely. This process is unfortunately time-consuming, but absolutely necessary to ensure that the cyber-attack does not continue at a later date.


The SAUTER websites have been affected by the emergency operation and are available again with immediate effect.


There are currently no concrete indications that our customers' infrastructures have been compromised in any way by SAUTER devices. It appears to be an opportunistic incident with no clearly recognisable long-term goals or systematic attacks. The situation does not currently suggest that there is a targeted, sustained threat to the affected systems.