How energy efficiency is improved
Distributor for intelligent, energy-efficient control
Areas of use
Distribution of the power supply, the positioning signals and a shared time programme for room devices (analogue or with display) and thermal actuators.
For easy wiring of up to 6 or 10 zones in a panel heating system
For transferring switching signals from the unitary controllers for heating or heating/cooling
Individual forwarding of time commands or night set-back to the appropriate actuators; max. two time channels
With pump and boiler control
Pump logic with adjustable follow-on time for actuating the circulation pump
Integrated valve protection function
Input for temperature limiter or dew point monitor
LED status indicator
Pump control direction switching for NC/NO actuators
For connecting up to 18 actuators
Cable guidance, standard-compliant cord grip and screwless terminal connections
Easy, intuitive wiring and installation
TLC TECHNICAL SERVICE TRADING COMPANY LIMITED
219/8 Duong so 5 Khu pho 3, Binh Hung Hoa Ward Binh Tan District, Ho Chi Minh City, Vietnam. Tel. +84 (0) 90 2540 929 long.nt(at)tl-controls(dot)com http://www.tl-controls.com/ Sauter Building Control International GmbH Hans-Bunte-Strasse 15 DE-79108 Freiburg i. Br. Tel. +49 761 510 54 05 Fax +49 761 510 54 20 ms.sbci(at)de.sauter-bc(dot)com www.sauter-controls.comSAUTER Head Office was the target of a cyber security incident on November 20, 2024. SAUTER’s IT department immediately activated, well defined, internal emergency plans. All IT systems were completely isolated and shut down to successfully prevent the attack from spreading. External cybersecurity experts and data forensics specialists then began to check all systems and restore them securely. This process is unfortunately time-consuming, but absolutely necessary to ensure that the cyber-attack does not continue at a later date.
The SAUTER websites have been affected by the emergency operation and are available again with immediate effect.
There are currently no concrete indications that our customers' infrastructures have been compromised in any way by SAUTER devices. It appears to be an opportunistic incident with no clearly recognisable long-term goals or systematic attacks. The situation does not currently suggest that there is a targeted, sustained threat to the affected systems.
You need to load content from reCAPTCHA to submit the form. Please note that doing so will share data with third-party providers.
More Information