How energy efficiency is improved
For demand-based volume flow control of dual-channel systems in offices
Optimum use of energy thanks to RLP100 2-channel controller in combination with room operating units of the TSP, TSFP and TSSP series
Compatible with practically all currently-available mixing boxes
Suitable for explosion hazard zone 1 II 2 G T6
Conformity tested as per EN 13463-1 and EN 1127-1 (ex zone 1 II 2 G T6)
Controls constant, switchable or variable air volumes
Accurate, static differential pressure sensor with large measuring range
Front plate printed with circuit diagrams for easy identification of the controller functions
Compressed-air connections with Rp⅛” female thread
Special measuring connection for detecting the air volume
Low-pressure connections with dual-diameter connector for soft plastic tubing (internal Ø 4 and 6 mm)
2 inputs
Command variable
Day/night change-over or heating/cooling signal
3 outputs
Actual value, air volume
Activates two damper actuators, heating and cooling
1 adjuster for setting the sensor measuring range
2 setpoint adjusters for maximum and minimum limitation of the air volume
TLC TECHNICAL SERVICE TRADING COMPANY LIMITED
219/8 Duong so 5 Khu pho 3, Binh Hung Hoa Ward Binh Tan District, Ho Chi Minh City, Vietnam. Tel. +84 (0) 90 2540 929 long.nt(at)tl-controls(dot)com http://www.tl-controls.com/ Sauter Building Control International GmbH Hans-Bunte-Strasse 15 DE-79108 Freiburg i. Br. Tel. +49 761 510 54 05 Fax +49 761 510 54 20 ms.sbci(at)de.sauter-bc(dot)com www.sauter-controls.comSAUTER Head Office was the target of a cyber security incident on November 20, 2024. SAUTER’s IT department immediately activated, well defined, internal emergency plans. All IT systems were completely isolated and shut down to successfully prevent the attack from spreading. External cybersecurity experts and data forensics specialists then began to check all systems and restore them securely. This process is unfortunately time-consuming, but absolutely necessary to ensure that the cyber-attack does not continue at a later date.
The SAUTER websites have been affected by the emergency operation and are available again with immediate effect.
There are currently no concrete indications that our customers' infrastructures have been compromised in any way by SAUTER devices. It appears to be an opportunistic incident with no clearly recognisable long-term goals or systematic attacks. The situation does not currently suggest that there is a targeted, sustained threat to the affected systems.
You need to load content from reCAPTCHA to submit the form. Please note that doing so will share data with third-party providers.
More Information